  • High Sensitivity 0.001 Differential Scanning Calorimeter DSC with Cooling System
  • High Sensitivity 0.001 Differential Scanning Calorimeter DSC with Cooling System
  • High Sensitivity 0.001 Differential Scanning Calorimeter DSC with Cooling System
  • High Sensitivity 0.001 Differential Scanning Calorimeter DSC with Cooling System
  • High Sensitivity 0.001 Differential Scanning Calorimeter DSC with Cooling System
  • High Sensitivity 0.001 Differential Scanning Calorimeter DSC with Cooling System
Find Similar Products
  • Overview
  • Product Description
  • Features
  • Our Advantages
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
DSC-100
Certification
CE, TUV, ISO
Warranty
2 Years
DSC Range
0~ +-600 Temp
Temperature Range
-Rt ~ 800 Temp
Heating Rate
0.1~80 Temp/Min
Temperature Resolution
0.001temp
Temperature Fluctuation
+- 0.001temp
DSC Sensitivity
0.01MW
Product Name
DSC Differential Scanning Calorimeter with Chiller
Function
Glass Transition Temperature, Crystallization, pH
Transport Package
Wooden Case
Specification
Customized
Trademark
Newgoer
Origin
Dongguan, China
HS Code
9027899090
Production Capacity
200

Product Description

Product Description


RT ~ 800C Differential Scanning Calorimeter dsc crucible differential scanning calorimeters
DSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control. DSC research and development includes the following field: glass transition temperature, melting point, cold crystallization, crystallization, phase transition, oxidation induction time (OIT).
 
Standards:
ISO/TR10837:1991, ASTM D3895-1998, ASTM E 967, ASTM E 968, ASTM E 793, ASTM D 3895, ASTM D 3417, ASTM D 3418, ISO 11357-6 ETC...
 

Model
 
DSC-100
 
DSC-100L
 
DSC-300
 
DSC-300L
 
DSC-300C
 
Temperature Range
 
RT ~ 800ºC
 
-100 ~ 800ºC
 
RT ~ 550ºC
 
-150 ~ 600ºC
 
-40 ~ 600ºC
 
DSC Range 
 
0~± 600mW
 
0~± 600mW
 
0~± 600mW
 
0~± 600mW
 
0~± 800mW
 
Cooling Method
 
Air Cooled
 
Liquid Nitrogen Cooled
 
Air Cooled
 
Liquid Nitrogen 
Cooled
 
Mechanical 
Cooled
 
Scanning Method
 
Heating Scan
 
Heating Scan
 
Heating Scan + Cooling Scan
  
High Sensitivity 0.001 Differential Scanning Calorimeter DSC with Cooling SystemHigh Sensitivity 0.001 Differential Scanning Calorimeter DSC with Cooling System
Details Images
The Differential Scanning Calorimeter DSC refers to in the temperature control program and a certain atmosphere, measuring the temperature difference between the sample and the reference material is proportional to the rate of heat flow through the thermal plate instrument.
High Sensitivity 0.001 Differential Scanning Calorimeter DSC with Cooling System
High Sensitivity 0.001 Differential Scanning Calorimeter DSC with Cooling System
High Sensitivity 0.001 Differential Scanning Calorimeter DSC with Cooling System
 
New designed oven structure, ensures high precision and good stability.
Two way controlled: Host control and Software control with friendly interface.
Air flow meter can control the air flow rate accurately, data can be recorded.

et

Features

1. The industrial-grade 7-inch touch screen displays rich information.
2. Brand-new metal furnace body structure, with better baseline and higher accuracy. The heating adopts indirect conduction method, which has high uniformity and stability, reduces pulse radiation, and is better than traditional heating mode.
3. USB communication interface, strong versatility, reliable and uninterrupted communication, supports self-recovery connection function.
4. Automatically switch the two-channel atmosphere flow, fast switching speed and short stabilization time. At the same time, a protective gas input is added.
5. The software is simple and easy to operate.
6. Mechanical cooling via low temperature thermostatic bath, better controlled with good linear curve. It can be reused to save costs than liquid nitrogrn.


Product Usage
 

High Sensitivity 0.001 Differential Scanning Calorimeter DSC with Cooling System
Melting Point (Enthalpy) Measurement
Melting point is transition temperature of the material from the liquid crystal phase; the thermal analysis measured the most common one physical data. The measurement accuracy and thermodynamic equilibrium temperature error is up to ± 1 ºC or so. ICTA recommended method is currently used to measure the melting of a solid material endothermic peak.
Glass Transition Temperature Measurement
Glass is a substance into a glass-like amorphous body (glassy) process; glassy state is a state between liquid and solid. In this aspect there is no crystal structure. DSC determination of the glass transition temperature Tg is based on this nature that polymer at the glass transition temperature, its heat capacity will increase. In the DSC curve, and its performance: when through the glass transition temperature, baseline to the endothermic direction.
High Sensitivity 0.001 Differential Scanning Calorimeter DSC with Cooling System
High Sensitivity 0.001 Differential Scanning Calorimeter DSC with Cooling System
High Sensitivity 0.001 Differential Scanning Calorimeter DSC with Cooling System

Comments from our clients !!!
High Sensitivity 0.001 Differential Scanning Calorimeter DSC with Cooling SystemHigh Sensitivity 0.001 Differential Scanning Calorimeter DSC with Cooling System
 

Our Advantages

 
High Sensitivity 0.001 Differential Scanning Calorimeter DSC with Cooling System
 
High Sensitivity 0.001 Differential Scanning Calorimeter DSC with Cooling System
 
 
High Sensitivity 0.001 Differential Scanning Calorimeter DSC with Cooling System
 

Packaging & Shipping

 
High Sensitivity 0.001 Differential Scanning Calorimeter DSC with Cooling System
 
We have packing teams and shipping forwarder to pack and deliver your products!

Packing:
1. Out packing:Standard export wooden case.
2. Inner packing:With careful stretch film wrap product, hard wood board+ strong bandage to fix corners.
3. Checking teams: Specialized staff to inspect and classified your goods.


Shipping:
You can specify other shipping methods such as Airmail, FEDEX or DHL. We shall let you know about the shipping cost after receipt of your order. It's more preferable for you to provide us with your own FEDEX/DHL account number so that the delivery charge can be charged directly from your account.
IEC60695 Glow Wire Flammability Temperature Tester, Glow Wire Combustion Resistance Testing Machine, Glow Wire Burning Tester.

FAQ

1.Are your company a trading one or a factory ?

Factory + trade (integration), 20 years focusing on test instruments field, 6 years exporting experience.
OEM is also acceptable for us.

2.How to choose the most suitable products?
Our team will give you the best suggestion as long as you tell us what kind of test you need to do and the required specification.

3.What's the delivery term?
At most of time, we have stock in the factory. If there is no stock, normally, the delivery time is 15-20 working days after deposit receipt. If you are in urgent need, we can consider making special arrangement for you.

4.Do you accept customization service?
Yes, of course, we can not only offer standard machines, but also customized machines according to your request. Don't hesitate to tell us your requirement, we will try our best to meet your needs.

5.Can we visit your factory before order?
Yes, we warmly welcome and sincerely invite you or your team to visit our factory, we will help to arrange hotel and pick up you from airport.
 
High Sensitivity 0.001 Differential Scanning Calorimeter DSC with Cooling System
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier